Request a Quote
Request a Quote
Fiberglass Cooling Towers

Berg’s line of fiberglass industrial cooling towers are manufactured of extra thick fiberglass and premium quality components to provide years of trouble-free, low maintenance performance.

 

They feature a host of standard features and are supplied fully assembled on a structural steel integral base for easier installation and hook-up.

With a reliable and cost-effective design, the Berg Fiberglass Cooling tower is the machine of choice across a wide range of industries around the world.

System Highlights:

  • Low cost & installation
  • All towers shipped assembled in two pieces (the body and fan assembly), ready for quick installation
  • Structural steel base standard
  • Thick fiberglass reinforced polyester castings and water basins have UV-inhibitor in gel coat to eliminate fiberglass deterioration and pigment fade
  • High efficiency P.V.C. fill and standard NEMA frame T.E.F.C. motors. No belt or gear reducers, low horsepower
  • Stainless steel internal framing and hardware
  • One piece water distributor, no moving parts, non-clogging design
  • P.V.C. drift eliminators
  • Non-ferrous inlet baffles
  • Entirely factory assembled on a steel base frame
  • Stainless Steel internal hardware and framing
  • Non-Clogging water distribution with access panels on tower for nozzle/fill access
  • Corrosion-Free Fiberglass Reinforced Polyester Shell and Base, with UV inhibitor
  • Rigid PVC fill for up to 130°F operating water
  • Standard NEMA frame, TEFC low speed motor(s)
  • Induced Draft counterflow design
  • Rigid PVC drift eliminators and inlet baffles
  • Nominal Cooling Capacity is based on 95°F entering water, 85°F leaving water, and 78°F wet bulb
  • No additional surface treatments are required to prolong the life of the tower.
  • Tower has a nozzle spray header that can be pressurized. Excess flow does not “overflow”.
  • PVC fill is enclosed with minimal exposure to U.V rays and wind. This will help detour the growth of algae and reduce the usage of biocides. Elimination of wind exposure prevents the fill from being coated with sleet or freezing rain during off periods in winter

Read more

  • Fans are direct drive. No belts or gearboxes to service.
  • Induced draft - counter flow design provides stable temperature control.
  • Fan assemblies shipped loose for field placement and fastening to top of tower.
  • Aluminum ladder for access to the top of the tower (for an additional cost)
  • Tower Stand (for an additional cost depending on height requirements and platforms requested)

“Industrial” dictates ruggedness. The Berg Tower is extremely rugged and the weight alone (amount of material that is used to make the unit) is a logical clue to that. The additional material in the Berg Towers consists of the thickness of the fibreglass ¼”, stainless steel supports inside the shell, and the steel base the unit sits on. All this is the recipe for longevity.

The Berg Units will be around 7500 lbs (operating), 4000 lbs (shipping -- ships in 2 pieces).

SPECIFICATIONS PER (1) ONE TOWER : Model BT-9636-7-1/2

COOLING TOWER – Induced Draft 106 ton
Cooling Capacity each 318 USGpm , 95F in/85F out @ 78F wetbulb
Electrical (V/Ph/Hz) 575V/3/60
Weight each 7,400 lbs operating / 3,400 lbs shipping
Fan Motor each 7-1/2 hp , 1800 rpm, TEAO
Tower Dimensions each 96” x 96” x 12’H
Ladder Extra $ 850.00
Water Connections 4” Top Side Inlet / 6” Bottom Outlet

SPECIFICATIONS PER (1) ONE TOWER : Model BT-9636-10

COOLING TOWER – Induced Draft 137 ton
Cooling Capacity each 411 USGpm , 95F in/85F out @ 78F wetbulb
Electrical (V/Ph/Hz) 575V/3/60
Weight each 7,500 lbs operating / 3,500 lbs shipping
Fan Motor each 10 hp , 1800 rpm, TEAO
Tower Dimensions each 96” x 96” x 12’H
Ladder Extra $ 850.00
Water Connections 4” Top Side Inlet / 6” Bottom Outlet

 

SPECIFICATIONS PER (1) ONE TOWER : Model BT-9636-15

COOLING TOWER – Induced Draft 150 ton
Cooling Capacity each 450 USGpm , 95F in/85F out @ 78F wetbulb
Electrical (V/Ph/Hz) 575V/3/60
Weight each 7,500 lbs operating / 4,000 lbs shipping
Fan Motor each 15 hp , 1800 rpm, TEAO
Tower Dimensions each 96” x 96” x 12’H
Ladder Extra $ 850.00
Water Connections 4” Top Side Inlet / 6” Bottom Outlet
4 Walkway (Full Perimeter Walkway) Stand (12ft high) with caged access ladder Single walkway (1 side only walkway) Stand (12 ft high*) with Caged access ladder For the Stand (12 ft high*) (no ladder/walkway/railings)
Freight available (for an additional cost) Freight available (for an additional cost) Freight available (for an additional cost)
Stand ships disassembled with all fastening hardware in crated boxes (see pics below). Assembly on site not included. Stand ships disassembled with all fastening hardware in crated boxes (see pics below). Assembly on site not included. Stand ships disassembled with all fastening hardware in crated boxes (see pics below). Assembly on site not included.
Requires proper foundation (either full concrete pad or 16” diameter concrete piers to below frost line and engineered for site conditions by others). Requires proper foundation (either full concrete pad or 16” diameter concrete piers to below frost line and engineered for site conditions by others). Requires proper foundation (either full concrete pad or 16” diameter concrete piers to below frost line and engineered for site conditions by others).
12 ft high stand assumes ground levels are the same between the plant and stand location for a 5 ft high tank inside (see below diagram) *12 ft high stand for ground levels that are the same between the plant and stand location, for a 5 ft high tank inside (see below diagram) *12 ft high stand for ground levels that are the same between the plant and stand location, for a 5 ft high tank inside (see below diagram)

4 Walkway

Single Walkway

No Ladder/Walkway

Pump Tank Systems

  • Berg also provides accompanying pump tank systems for our fiberglass cooling towers to ensure that we provide you with best, optimal solutions for your facility.
  • Berg offers complete flexibility in pump/tank assembly designs to customize both dimensions and capacity for any industrial application. Reservoirs are available in mild and stainless steel, mounted on a heavy structural steel base, and have steel banding for additional structural support for the reservoir.
  • Pumps can be single-end mounted or dual-end mounted. Single pumps to multiple pumps complete with pipe headers are available. For large pump/tank assemblies, the pump assembly can be designed to be separate from the reservoir for installation and shipping constraints.

Cooling Towers

Take a look at some of the custom cooling towers Berg has provided to clients across various industries throughout the years.

Find out how Berg’s cooling towers can help your company’s production process. Contact a Berg representative today.